Detalhes do Incidente DADOS
📅 Abertura: 2026-01-31 23:31:09-03:00
⏱️ Próxima Atualização:
EVENTO #2405
📍 Roteador A (Origem)
Hostname: RNDISPO-SPO02-01-100GE0/11/0
Fabricante: HUAWEI
Status:
UP
Alarme: [TELCO][BBIP] INPUT BANDWITH UTILIZATION
⚡ Serviço / Falha
ACCID / CIRCUITO
574033
TIPO DE FALHA
None
🎯 Roteador B (Destino)
Hostname: RNCOSPO0301-100GE8/0/3
Fabricante: HUAWEI
Status:
UP
Alarme: [TELCO][BBIP] INPUT BANDWITH UTILIZATION
🔗 Rota Física (Camada TX)
-
Salto 1SPO-VMA01-THWW05
-
Salto 2SPO-CVO01-THWW11
📝 Relatório de Acionamento (Texto Padrão)
Solicito apoio técnico para verificação de alarme no ACCID Dados (Circuito): "574033" com a falha de "Tipo de Falha: Link Down".
O circuito começa em (Roteador A (Origem): RNDISPO-SPO02-01-100GE0/11/0. Status: UP, Fabricante: HUAWEI, Alarme Ativo: [TELCO][BBIP] INPUT BANDWITH UTILIZATION) indo ate (Roteador B (Destino): RNCOSPO0301-100GE8/0/3. Status: UP, Fabricante: HUAWEI, Alarme Ativo: [TELCO][BBIP] INPUT BANDWITH UTILIZATION).
Onde a rota física passa por (ROTA FÍSICA (ELEMENTOS TX UTILIZADOS)):
SPO-VMA01-THWW05 -> SPO-CVO01-THWW11
Informações Extras / Rascunho:
[TELCO][BBIP] Input bandwith utilization
RNDISPO-SPO02-01-100GE0/11/0
31/01/26 22:46:36
100GE0/11/0
CONEXAO AO CORE|RNCOSPO0301|HU8/0/3|ACCID 574033|NONE|ACT|NONE
<RNDISPO-SPO02-01>display interface 100GE0/11/0
100GE0/11/0 current state : UP (ifindex: 36)
Line protocol current state : UP
Link quality grade : GOOD
Description: CONEXAO AO CORE|RNCOSPO0301|HU8/0/3|ACCID 574033|NONE|ACT|NONE
Route Port,The Maximum Transmit Unit is 9100
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 2087-ec5b-0020
Factor/Module: QSFP28, Standard: 100GBASE-ER4, FecMode: Disable
The Vendor PN is OM9558ES100
The Vendor Name is HISILICON
Port BW: 100G, Transceiver max BW: 100G, Transceiver Mode: SingleMode
Connector Type: LC, Transmission Distance: 40km
WaveLength: 1295.56nm 1300.05nm 1304.58nm 1309.14nm
Rx Warning range: [-20.915, -3.500]dBm, Tx Warning range: [-2.900, 2.899]dBm
Rx0 Power: -10.86dBm, Tx0 Power: -0.38dBm
Rx1 Power: -10.71dBm, Tx1 Power: -0.28dBm
Rx2 Power: -10.32dBm, Tx2 Power: -0.08dBm
Rx3 Power: -10.15dBm, Tx3 Power: 0.17dBm
<RNCOSPO0301>display interface 100GE8/0/3
100GE8/0/3 current state : UP (ifindex: 234)
Line protocol current state : UP
Link quality grade : GOOD
Description: CONEXAO AO DIST|RNDISPO-SPO02-01|100GE0/11/0|574033|DIS SPO02|ACT|NONE
Route Port,The Maximum Transmit Unit is 9100
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is ecc0-1b7a-42ad
Factor/Module: QSFP28, Standard: 100GBASE-LR4, FecMode: Disable
The Vendor PN is SQF1012L4LNH102B
The Vendor Name is SumitomoElectric
Port BW: 100G, Transceiver max BW: 100G, Transceiver Mode: SingleMode
Connector Type: LC, Transmission Distance: 10km
WaveLength: 1295.56nm 1300.05nm 1304.58nm 1309.14nm
Rx Warning range: [-7.999, 4.500]dBm, Tx Warning range: [-2.500, 4.000]dBm
Rx0 Power: 0.01dBm, Tx0 Power: 2.52dBm
Rx1 Power: 0.32dBm, Tx1 Power: 2.46dBm
Rx2 Power: -0.19dBm, Tx2 Power: 2.06dBm
Rx3 Power: 0.07dBm, Tx3 Power: 1.75dBm