Detalhes do Incidente DADOS
📅 Abertura: 2026-02-06 00:04:41-03:00
⏱️ Próxima Atualização:
EVENTO #2470
📍 Roteador A (Origem)
Hostname: TSA-LNA01-NKI01CO - 1/1/6
Fabricante: NOKIA
Status:
UP
Alarme: Sem alarme
⚡ Serviço / Falha
ACCID / CIRCUITO
575332
TIPO DE FALHA
None
🎯 Roteador B (Destino)
Hostname: PTA-VOO01-NKI01CO - 3/1/3
Fabricante: CISCO
Status:
UP
Alarme: Sem alarme
🔗 Rota Física (Camada TX)
-
Salto 1TSA-LNA01-NKW03
-
Salto 2DVB-LRA01-NKW01
-
Salto 3ABA-TPA01-NKW01/AA2DONW-1-8-LINE
-
Salto 4RGE-ALN01-NKW01/AA2DONW-1-8-LINE
-
Salto 5FLO-GRO01-NKW01/AHPHG-1-2-LINE
-
Salto 6IUY-ALO01-NKW01/AHPHG-1-4-LINE
-
Salto 7CII-BVA01-NKW01/AHPHG-1-4-LINE
-
Salto 8SRN-JDS01-NKW01/AHPHG-1-4-LINE
-
Salto 9CGR-SSO01-NKW01/AHPHG-1-4-LINE
-
Salto 10REM-VSA01-NKW01/AHPHG-1-2-LINE
-
Salto 11CSV-QAZ01-NKW01/AHPHG-1-4-LINE
-
Salto 12PTA-VOO01-NKW01
📝 Relatório de Acionamento (Texto Padrão)
Solicito apoio técnico para verificação de alarme no ACCID Dados (Circuito): "575332" com a falha de "Tipo de Falha: Link Down".
O circuito começa em (Roteador A (Origem): TSA-LNA01-NKI01CO - 1/1/6. Status: UP, Fabricante: NOKIA, Alarme Ativo: N/A) indo ate (Roteador B (Destino): PTA-VOO01-NKI01CO - 3/1/3. Status: UP, Fabricante: NOKIA, Alarme Ativo: N/A).
Onde a rota física passa por (ROTA FÍSICA (ELEMENTOS TX UTILIZADOS)):
TSA-LNA01-NKW03 -> DVB-LRA01-NKW01 -> ABA-TPA01-NKW01/AA2DONW-1-8-LINE -> RGE-ALN01-NKW01/AA2DONW-1-8-LINE -> FLO-GRO01-NKW01/AHPHG-1-2-LINE -> IUY-ALO01-NKW01/AHPHG-1-4-LINE -> CII-BVA01-NKW01/AHPHG-1-4-LINE -> SRN-JDS01-NKW01/AHPHG-1-4-LINE -> CGR-SSO01-NKW01/AHPHG-1-4-LINE -> REM-VSA01-NKW01/AHPHG-1-2-LINE -> CSV-QAZ01-NKW01/AHPHG-1-4-LINE -> PTA-VOO01-NKW01
Informações Extras / Rascunho:
Interface Down
TSA-LNA01-NKI01CO - 1/1/6
03/02/26 00:12:04
ANEL NAO ENCONTRADO
1/1/6
conexao ao PTA-VOO01-NKI01CO ; port 10G_3/1/3; LC 575332; FTTCBBIP
A:TSA-LNA01-NKI01CO# show port 1/1/6
===============================================================================
Ethernet Interface
===============================================================================
Description : conexao ao PTA-VOO01-NKI01CO ; port 10G_3/1/3; LC 575332;
FTTCBBIP
Interface : 1/1/6 Oper Speed : 10 Gbps
Link-level : Ethernet Config Speed : N/A
Admin State : up Oper Duplex : full
Oper State : down Config Duplex : N/A
Physical Link : No MTU : 9212
Single Fiber Mode : No Min Frame Length : 64 Bytes
IfIndex : 35848192 Hold time up : 5 seconds
Last State Change : 02/03/2026 01:30:23 Hold time down : 0 seconds
Last Cleared Time : N/A DDM Events : Enabled
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated
===============================================================================
Value High Alarm High Warn Low Warn Low Alarm
-------------------------------------------------------------------------------
Temperature (C) +33.6 +95.0 +93.0 -48.0 -50.0
Supply Voltage (V) 3.31 3.80 3.60 3.00 2.80
Tx Bias Current (mA) 33.4 120.0 110.0 3.0 1.0
Tx Output Power (dBm) -1.94 2.00 1.00 -7.00 -8.00
Rx Optical Power (avg dBm) -3.67 1.50 1.00 -19.00 -21.02
===============================================================================
A:PTA-VOO01-NKI01CO# show port 3/1/3
===============================================================================
Ethernet Interface
===============================================================================
Description : conexao ao TSA-LNA01-NKI01CO ; port 10G_1/1/6; LC 575332;
FTTCBBIP
Interface : 3/1/3 Oper Speed : 10 Gbps
Link-level : Ethernet Config Speed : N/A
Admin State : up Oper Duplex : full
Oper State : down Config Duplex : N/A
Physical Link : No MTU : 9212
Single Fiber Mode : No Min Frame Length : 64 Bytes
IfIndex : 102858752 Hold time up : 5 seconds
Last State Change : 02/03/2026 01:30:22 Hold time down : 0 seconds
Last Cleared Time : 08/04/2025 10:10:07 DDM Events : Enabled
Phys State Chng Cnt: 30354
RS-FEC Config Mode : None
RS-FEC Oper Mode : None
===============================================================================
Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated
===============================================================================
Value High Alarm High Warn Low Warn Low Alarm
-------------------------------------------------------------------------------
Temperature (C) +30.3 +75.0 +70.0 +0.0 -5.0
Supply Voltage (V) 3.31 3.63 3.46 3.13 2.97
Tx Bias Current (mA) 41.3 70.0 68.0 2.0 1.0
Tx Output Power (dBm) -2.43 3.50 0.50 -8.20 -12.20
Rx Optical Power (avg dBm) -3.29 3.50 0.50 -14.40 -18.39
===============================================================================