Relatório de Eventos
Visualize e gerencie todos os eventos registrados no sistema.
| ID | Título do Evento | Descrição Resumida | Abertura | Tipo | Ações |
|---|---|---|---|---|---|
| 2571 |
EVE260200077221 |
Abertura do Enlace entre "IRARA-BA" para "SERRINHA-BA". (ANEL: WDM_LD_CT_SECAO_Q)
ELEMENTO 1: IRX-ESA01-CTW01 - Line Rx ( OTS-TTP Sk ) 00-1-007.1
ELEMENTO 2: SEH-HRO01-CTW01 - Line Tx ( OTS-TTP Src ) 00-1-005.2
Alarme Elemento 1: Loss of Signal (LOS)
Alarmes Elemento Vizinho: Communication Link Failure with NE (COMFAIL)
ACCID/LC: Não informado.
Swap de Fibra: MOB TELECOM - Protocolo ant - 13082025-17860
Informações extras: .
FALHA DUPLA:
IRX-ESA01-CTW01
X
ALH-DJO01-CTW02
TAMBEM COM ALARMES NO MESMO HORARIO.
--- Regra do Teste OTDR ---
Teste OTDR em curso: Nao.
Acionado equipe SOM. Próxima atualização às: 01:12.
|
13/02/2026 23:42 | Abertura de Enlace | Ver Detalhes |
| 2570 |
EVE260200055791 |
Solicito apoio técnico para verificação de alarme no ACCID Dados (Circuito): "620809" com a falha de "Tipo de Falha: Link Down".
O circuito começa em (Roteador A (Origem): RTICSNE0103 - HundredGigE0/1/0/12. Status: UP, Fabricante: CISCO, Alarme Ativo: INTERFACE DOWN) indo ate (Roteador B (Destino): RTICBHE0203 - HundredGigE0/0/0/22. Status: UP, Fabricante: CISCO, Alarme Ativo: INTERFACE DOWN).
Onde a rota física passa por (ROTA FÍSICA (ELEMENTOS TX UTILIZADOS)):
SNE-AGO01-HWW10 -> BHE-GTC01-HWW13
Informações Extras / Rascunho:
Interface Down
RTICSNE0103 - HundredGigE0/1/0/12
13/02/26 22:45:09
HundredGigE0/1/0/12
CONEXAO AO BBIP|RTICBHE0203 - HundredGigE0/0/0/22|620809|BBIP|ACT|VIA3-NSOID73382
RP/0/RP0/CPU0:RTICSNE0103#show interfaces HundredGigE0/1/0/12
Fri Feb 13 23:03:26.698 -03
HundredGigE0/1/0/12 is down, line protocol is down
Interface state transitions: 2048
Dampening enabled: penalty 0, not suppressed
half-life: 1 reuse: 750
suppress: 2000 max-suppress-time: 4
restart-penalty: 0
Hardware is HundredGigE, address is 6879.0966.1f40 (bia 6879.0966.1f40)
Description: CONEXAO AO BBIP|RTICBHE0203|HundredGigE0/0/0/22|620809|BBIP|ACT|VIA3-NSOID73382
Internet address is Unknown
MTU 9100 bytes, BW 100000000 Kbit (Max: 100000000 Kbit)
reliability 255/255, txload 0/255, rxload 0/255
Encapsulation ARPA,
Full-duplex, 100000Mb/s, 100GBASE-LR4, link type is force-up
output flow control is off, input flow control is off
Carrier delay (up) is 2000 msec
loopback not set,
Last link flapped 00:23:02
Last input 00:23:02, output 00:23:02
Alarms key: (H) Alarm high, (h) Warning high
(L) Alarm low, (l) Warning low
Wavelength Tx Power Rx Power Laser Bias
Lane (nm) (dBm) (mW) (dBm) (mW) (mA)
-- ----- ------ ------ ------ ------ ------
0 n/a -40.0 0.0001 0.9 1.2224 0.000
1 n/a -40.0 0.0001 0.7 1.1687 0.000
2 n/a -40.0 0.0001 1.4 1.3893 0.000
3 n/a -40.0 0.0001 1.4 1.3652 0.000
RP/0/RP0/CPU0:RTICBHE0203#show interfaces HundredGigE0/0/0/22
Fri Feb 13 23:20:58.065 -03
HundredGigE0/0/0/22 is down, line protocol is down
Interface state transitions: 2918
Dampening enabled: penalty 0, not suppressed
half-life: 1 reuse: 750
suppress: 2000 max-suppress-time: 4
restart-penalty: 0
Hardware is HundredGigE, address is dc0b.0921.1a74 (bia dc0b.0921.1a74)
Description: CONEXAO AO BBIP|RTICSNE0103|HundredGigE0/1/0/12|620809|BBIP|ACT|VIA3-NSOID73382
Internet address is Unknown
MTU 9100 bytes, BW 100000000 Kbit (Max: 100000000 Kbit)
reliability 255/255, txload 0/255, rxload 0/255
Encapsulation ARPA,
Full-duplex, 100000Mb/s, 100GBASE-LR4, link type is force-up
output flow control is off, input flow control is off
Carrier delay (up) is 2000 msec
loopback not set,
Last link flapped 00:40:34
Last input 00:40:34, output 00:40:34
RP/0/RP0/CPU0:RTICBHE0203#show controllers HundredGigE0/0/0/22
Fri Feb 13 23:21:25.911 -03
Operational data for interface HundredGigE0/0/0/22:
State:
Administrative state: enabled
Operational state: Down (Reason: Link loss or low light, no loopback)
LED state: Yellow On
Phy:
Media type: R fiber over 4 Lane optics (long reach)
Optics:
Vendor: CISCO-FINISAR
Part number: FTLC1154RDPL-C1
Serial number: FNS2633018U
Wavelength: 1302 nm
Digital Optical Monitoring:
Transceiver Temp: 40.757 C
Transceiver Voltage: 3.248 V
Alarms key: (H) Alarm high, (h) Warning high
(L) Alarm low, (l) Warning low
Wavelength Tx Power Rx Power Laser Bias
Lane (nm) (dBm) (mW) (dBm) (mW) (mA)
-- ----- ------ ------ ------ ------ ------
0 n/a 1.7 1.4818 -0.8 0.8350 40.650
1 n/a 2.8 1.8923 -1.0 0.7898 40.276
2 n/a 1.8 1.5272 -0.8 0.8306 40.664
3 n/a 2.0 1.5842 -1.1 0.7725 41.072
|
13/02/2026 23:22 | BBIP/DADOS | Ver Detalhes 🔍 |
| 2569 |
EVE260200076995 |
Solicito apoio técnico para verificação de alarme no ACCID Dados (Circuito): "535341" com a falha de "Tipo de Falha: Link Down".
O circuito começa em (Roteador A (Origem): RPO-TBA01-HWI01CO - GigabitEthernet0/6/1. Status: UP, Fabricante: HUAWEI, Alarme Ativo: INTERFACE DOWN) indo ate (Roteador B (Destino): SRR-TDE01-HWI01CO - GigabitEthernet0/6/0. Status: UP, Fabricante: CISCO, Alarme Ativo: INTERFACE DOWN).
Onde a rota física passa por (ROTA FÍSICA (ELEMENTOS TX UTILIZADOS)):
RPO-TBA01-HWW05 -> SRR-TDE01-HWW01-Shelf0-29-N4SLQ64-1
Informações Extras / Rascunho:
Interface Down
RPO-TBA01-HWI01CO - GigabitEthernet0/6/1
13/02/26 21:54:02
Conexao ao SRR-TDE01-HWI01CO GE 0/6/0 - LC 535341
<RPO-TBA01-HWI01CO>display interface GigabitEthernet0/6/1
GigabitEthernet0/6/1 current state : DOWN(remote fault) (ifindex: 591)
Line protocol current state : DOWN
Link quality grade : --
Description: Conexao ao SRR-TDE01-HWI01CO GE 0/6/0 - LC535341
Route Port,The Maximum Transmit Unit is 1500
Internet Address is 10.40.82.129/31
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 340a-98cf-8248
The Vendor PN is RTXM228-401
The Vendor Name is WTD
Port BW: 10G, Transceiver max BW: 10G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km
Rx Power: -4.95dBm, Warning range: [-14.400, 0.499]dBm
Tx Power: -3.88dBm, Warning range: [-8.198, 0.499]dBm
<SRR-TDE01-HWI01CO>display interface GigabitEthernet0/6/0
GigabitEthernet0/6/0 current state : DOWN(PCS fault) (ifindex: 599)
Line protocol current state : DOWN
Link quality grade : --
Description: description Conexao ao RPO-TBA01-HWI01CO GE 0/6/1 - LC535341
Route Port,The Maximum Transmit Unit is 1500
Internet Address is 10.40.82.128/31
IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is d0ef-c1e7-f9e1
The Vendor PN is RTXM228-401
The Vendor Name is WTD
Port BW: 10G, Transceiver max BW: 10G, Transceiver Mode: SingleMode
WaveLength: 1310nm, Transmission Distance: 10km
Rx Power: -2.83dBm, Warning range: [-14.400, 0.499]dBm
Tx Power: -1.91dBm, Warning range: [-8.198, 0.499]dBm
|
13/02/2026 22:50 | BBIP/DADOS | Ver Detalhes 🔍 |